Skip to content
Core field area: İstanbul Anatolian & Kocaeli corridor · Outside corridor by agreed quote
SS-PRE · EN 1090 Hangar Sample SSR-2026-PEB-03 8 min read

Steel Warehouse, Factory & Hangar (EN 1090) Pre-Shipment Sample Report

Examine how SerSourcing executes a Pre-shipment Check (SS-PRE €490) on fabricated heavy portal columns, rafters, wind bracings and Z-purlins before your final balance transfer and mega-trailer / container dispatch.

Open-access preview — zero email wall or newsletter spam.

Founder Technical & Procurement Review Tariff & Scope Verified: 2026-11-02
Prepared by Celalettin YAĞMAHAN Civil Engineer
Reviewed by İdris YAĞMAHAN Architect

Reviewed for technical terminology, Turkish factory field reality and published EUR scope boundaries (not statutory engineering sign-off).

Active Corporate Specimen: SSR-2026-PEB-03 · Steel Hangar PSI Report
Commission This Scope on WhatsApp
SerSourcing TECHNICAL SOURCING, FACTORY AUDIT & BUYING-OFFICE DIVISION
DOCUMENT CONTROL Page 1 / 2
Document Ref.
SSR-2026-PEB-03
Tariff / Scope
SS-PRE (€490 · 1 Site / Up to 4h On-Site PSI)
Issue / Revision
Rev. 02 · 2026-11-02
Classification
SPECIMEN · NDA ANONYMIZED

PRE-SHIPMENT DIMENSIONAL, COATING & TRACEABILITY CHECK (PSI)

Product Scope: 1,800 m² Clear-Span Portal Steel Warehouse (S355JR Columns/Rafters, Z200 Purlins & EN 14399 10.9 Bolt Lots — ~74 Tons)

ILLUSTRATIVE CORPORATE SPECIMEN (ZERO CLIENT DATA DISCLOSED): Client names, factory identities, heat/certificate numbers and commercial figures in this specimen are fictionalized to protect strict B2B NDA confidentiality. Scoped commercial/visual engineering record — not an accredited laboratory test certificate or statutory structural sign-off.

01 · ASSIGNMENT REGISTER & EXECUTIVE GATE SUMMARY

Commissioning Buyer Profile [REDACTED — Industrial Logistics Park Investor, Bulgaria / EU]
Industrial Corridor & Travel Rule Gebze – Dilovası Heavy Steel Fabrication Zone, Kocaeli
Referenced Technical Standards EN 1090-2 EXC2 · EN 10025-2 S355JR · ISO 8501-1 Sa 2½ · ISO 12944 C3-M
Verification Instruments & Basis Magnetic Dry-Film Thickness (DFT) Gauge, Steel Tape (Class I), Digital Caliper, Weld Visual Gauge
Standard Tariff & Turnaround €490 (SS-PRE) · Target Delivery: 2 Business Days After Inspection
28 Members Sampled Columns, Rafters & Purlins
60 Readings Magnetic Paint DFT Points
±1.5 mm End-Plate Hole Pitch Delta
2 Rework Items Pre-Loading Hold Actions
Executive Gate Recommendation: HOLD DISPATCH UNTIL TOUCH-UP & BOLT NUT LOT VERIFIED

Primary portal columns (C-01..C-14) and rafters (R-01..R-14) match shop-drawing overall lengths and splice end-plate hole centers (±1.5 mm). However, 3 rafters showed low epoxy DFT (105–118 µm vs 160 µm spec) along bottom flange edges, and M24×85 Grade 10.9 HV nut/washer boxes lacked EN 14399 k-class batch labels.

02 · SCOPED TECHNICAL OBSERVATIONS, MEASUREMENTS & COMPARISON MATRIX

Ref. Subsystem / Inspection Parameter Buyer Specification / Benchmark Recorded Field / Desk Evidence Evidence Basis Required Buyer / Supplier Gate Action
CHK-01 Splice End-Plate Thickness & Bolt-Hole Pitch 25 mm S355JR end-plate; 26 mm holes @ 120×220 mm gauge (±2.0 mm) Sampled 8 rafters + 6 columns: plate thickness 25.1–25.3 mm; hole centers within ±1.5 mm; zero flame-cut oval holes. Observed / Verified Dimensional geometry accepted for site bolting.
CHK-02 Hard-Stamped Piece Marks vs. Erection Drawing Hard-stamped + tag-labeled member IDs (C-01..C-24, R-01..R-24) Hard stamps legible under primer/topcoat on all 14 sampled primary members; barcode tags wired. Observed / Verified Compliant; retain tag register in packing list.
CHK-03 ISO 12944 Epoxy/PU Coating Dry-Film Thickness (DFT) Nominal 160 µm total DFT (80% >=160 µm, min >=128 µm rule) Web faces averaged 174 µm; 3 rafters (R-04, R-09, R-11) measured 105–118 µm along lower flange edges. Open / Hold Gate Hold R-04, R-09, R-11 for stripe-coat rework + re-measurement photo.
CHK-04 EN 1090-1 FPC Certificate & Factory NDT Dossier Valid Notified Body FPC (EXC2), WPS/WPQR and UT/MT report on full-pen welds Reviewed Notified Body FPC cert, welder quals and third-party UT report #UT-882 covering haunch butt welds. Document Reviewed Include signed DoP + UT report PDF in final customs/handover binder.
CHK-05 Cold-Formed Roof Z-Purlins & Eave Struts Z200 × 2.00 mm S350GD+Z275 pre-punched sleeves, strapped on timber skids 4 sampled Z200 bundles measured 2.01–2.03 mm coated; zinc surface dry with zero white-rust staining. Observed / Verified Ready for loading; keep indoor storage until trailer arrival.
CHK-06 Anchor Bolts & EN 14399-3/4 Grade 10.9 HV Fasteners Sealed kegs with matching 10.9 bolt, nut & washer batch certificates + +5% spare M24 10.9 bolt kegs present, but 4 nut cartons were generic 8.8 stock instead of matched EN 14399 HR/HV 10.9 nuts. Open / Hold Gate Mandatory replacement with certified Class 10 HV nuts before truck loading.
Inspection & Sampling Basis

Scoped B2B visual field verification, random dimensional spot-sampling and documentary cross-check.

Metrology & Traceability

Field gauges zero-checked prior to measurement; heat/batch IDs cross-referenced against presented 3.1 MTCs.

Commercial Payment Gate Rule

Advance or balance wire release remains conditional upon closing all Open / Hold items logged on Sheet 2.

SerSourcing — Operated by CFY Mühendislik Mim. Dan. Yapı Malz. İnş. San. ve Tic. Ltd. Şti. · Maltepe, İstanbul SSR-2026-PEB-03 · Page 1 / 2
SerSourcing · CFY Mühendislik Mim. Dan. Yapı Malz. İnş. San. ve Tic. Ltd. Şti. CORPORATE ENGINEERING & PROCUREMENT DOSSIER — CONTINUATION SHEET
SSR-2026-PEB-03 Rev. 02 · 2026-11-02 Page 2 / 2

03 · CROSS-REFERENCED EVIDENCE & ANNEX REGISTER

MEAS-A1 Logged in Dossier
28-Member Dimensional & Splice Hole Check Sheet

Recorded web/flange/length/diagonal and end-plate hole pitch measurements vs. shop drawings.

DFT-B2 Logged in Dossier
60-Point Magnetic Coating Thickness Map

bay-by-bay DFT readings identifying R-04, R-09 and R-11 flange edge touch-up zones.

CERT-C3 Logged in Dossier
EN 1090-1 FPC, 3.1 Plate Heats & UT Weld Record Index

Cross-checked S355JR plate heat numbers and ultrasonic test report #UT-882.

BOLT-D4 Logged in Dossier
Fastener Keg & Anchor Template Count Log

Photographic log catching mismatched Class 8.8 nut cartons prior to dispatch.

04 · OPEN-ITEMS ACTION REGISTER BEFORE COMMERCIAL RELEASE

Item ID Open Technical / Commercial Point Action Owner Target Release Gate
OI-01 Apply polyurethane topcoat touch-up on R-04, R-09 and R-11 flange edges to >=160 µm DFT and submit gauge photos. Fabricator QC Before Trailer Loading
OI-02 Replace mismatched Class 8.8 nut cartons with EN 14399 Class 10 HV nuts + 3.1 fastener batch certificate. Fabricator Purchasing Before Balance Release
OI-03 Confirm timber spacer dunnage between painted rafters during 13.6 m mega-trailer loading (SS-LOAD €390). Fabricator / SerSourcing Loading Day

05 · EVIDENCE CLASSIFICATION KEY & CORPORATE SCOPE GOVERNANCE

Observed / Verified

Directly witnessed, counted or measured on site/desk by SerSourcing within the agreed assignment window.

Document Reviewed

Recorded from supplier-submitted certificates, MTCs or drawings without assuming physical lot testing.

Supplier-Stated

Verbal or written manufacturer statement recorded transparently; requires independent verification.

Open / Hold Gate

Unresolved technical or commercial hold item recommended for closure prior to stage payment/dispatch.

Governance & Independence Standard: Issued under buyer-representation tariff SS-2026-11-V2. Zero undisclosed supplier commission. Goods contracts, product warranties, accredited EN ISO/IEC 17025 lab testing and statutory engineering sign-off remain with the respective contracting parties and appointed specialists.

06 · DOCUMENT REVISION LOG & CONTROLLED DISTRIBUTION REGISTER

Rev. Date Revision Status & QA Milestone Authorized Distribution & Archive Retention
Rev. 01 2026-10-30 Initial field / desk observation log, dimensional check sheet & annex index. Internal Engineering Desk QA Review (Maltepe HQ)
Rev. 02 2026-11-02 QA-verified corporate engineering dossier & executive gate recommendation. Commissioning Buyer (1× Encrypted PDF + Annex ZIP) · 5-Yr NDA Archive

07 · BUYER CONTRACT, PAYMENT & DISPATCH SAFEGUARD PROTOCOL

GATE-01 Proforma & Technical Specification Rider

Bind verified steel grade, coating mass, tolerances and export packing rules directly into the signed Proforma Invoice.

GATE-02 Lot-Specific Certificate & Export Pack

Verify batch-allocated EN 10204 3.1 MTC, CE DoP, packing list and draft A.TR/EUR.1 48h prior to balance wire.

GATE-03 Pre-Shipment & Loading Gate Witness

Confirm final piece count and dunnage via SS-PRE (€490) or SS-LOAD (€390) before high-security bolt seal closure.

GATE-04 Strict NDA & Zero-Commission Mandate

Issued exclusively for commissioning buyer internal governance; SerSourcing accepts zero supplier commission (0%).

Prepared By (Field / Desk Lead) Celalettin YAĞMAHAN Civil Engineer · Co-Founder
Maltepe, İstanbul · 2026-11-02
Technical Quality Review By İdris YAĞMAHAN Architect · Co-Founder
QA Control · SSR-2026-PEB-03
Corporate Verification Seal
Tariff SS-2026-11-V2 · MERSİS: 0209128951200001 · Tax ID: 2091289512 · sersourcing.com SSR-2026-PEB-03 · Page 2 / 2

Why Pre-Shipment Inspection on EN 1090 Steel Saves Weeks of Crane Downtime Abroad

When a 75-ton pre-engineered steel warehouse or hangar arrives at a European, Balkan or African construction site with misaligned splice end-plate holes, peeling under-cured primer, or mismatched 8.8 nuts on 10.9 high-strength friction-grip bolts, mobile crane rental penalties quickly exceed €2,500 per day.

Commissioning SS-PRE (€490) before releasing the final factory balance catches dimensional, coating micron, and fastener-lot discrepancies while the steel is still on the Turkish shop floor.

  • Spot-checks critical portal column-to-rafter haunch splice plates and base-plate anchor hole geometry.
  • Records multi-point dry-film thickness (DFT) readings across webs, flanges and weld heat-affected zones.
  • Verifies EN 1090 DoP paperwork, EN 10204 3.1 heat traceability, and 10.9 fastener keg completeness.
More Corporate Deliverable Specimens

Explore Other Sector & Engineering Report Samples

SS-VISIT · LGSF Audit Sample

LGSF Villa Audit Report

Corporate factory audit specimen for a Turkish light-gauge steel villa (LGSF) roll-forming plant: S350GD+Z275 coil tag verification, BMT caliper checks, CNC dimple accuracy and subcontracting risk log.

SS-TECH · Modular Cabin Sample

Prefab Cabin Tech Report

Technical factory review specimen for flat-pack modular cabins, site camps and prefabricated homes: chassis welding jigs, PIR/EPS sandwich wall press, roof gutter drainage and flat-pack stacking.

SS-LOAD · Container CLS Sample

Panel Loading CLS Report

Container & mega-trailer loading supervision (CLS) corporate dossier for PIR/rockwool sandwich panels, flashings and steel purlins: empty container light/moisture check, 11.80 m bundle protection, ISPM-15 dunnage and bolt-seal log.

Continue Exploring
Clear Boundaries & Scope Answers

Frequently Asked Questions

No. SerSourcing conducts visual/dimensional spot checks, magnetic DFT paint thickness readings and document review of the fabricator’s third-party EN ISO 9712 NDT reports. Where independent accredited NDT is required, an ISO/IEC 17020/17025 body can be coordinated separately.

Fixed EUR Schedule · Free Initial Scope Review

Move your Türkiye purchase forward with a defined scope

Share your product specification, drawing or Turkish supplier details to receive a clear written scope and EUR fee confirmation before work starts.

WhatsApp Sourcing Desk